Development of a cutting edge temperature measurement of end mill tool by using infrared radiation technique

Abdullah, Yassin and Abang Mohammad Nizam, Abang Kamaruddin and Syed Tarmizi, Syed Shazali and M. Shahidul, Islam and Mohd Azrin, Mohd Said and Mohd A., Kiprawi (2019) Development of a cutting edge temperature measurement of end mill tool by using infrared radiation technique. Journal of Mechanical Engineering and Sciences, 3 (1). pp. 4661-4678. ISSN 2231-8380

[img] PDF
Development of a cutting edge temperature measurement of end mill tool by using infrared radiation technique. - Copy.pdf

Download (1MB)
Official URL: http://journal.ump.edu.my/jmes/article/view/1843

Abstract

This paper describes the development of cutting temperature measurement of end mill tool by using infrared radiation technique approach. Compared to conventional thermocouple technique, infrared radiation technique is an advance method of measuring temperature which featured high accuracy, high response rate, wide range of temperature scale detection and almost compatible with all materials used in the manufacturing industry. We measures the emission of infrared radiation from the source, which is cutting edge of tool by using photocells that contains InAs and InSb photovoltaic detectors. Photocells converts the infrared radiation to a voltage signal and then recorded by oscilloscope followed with a calibration with its corresponding temperature. This paper discussed about the calibration method, cutting experiment setup, the limit of infrared radiation level detected by photocells, signal correction of output signal, and relations of peak signal formation with rotation of end mill tool. The developed pyrometer is also capable to profile the cutting tool’s rotation based on the movements of infrared radiation’s emission at cutting tool’s edge. The conclusion was that the measurement of cutting temperature of high speed machining by using infrared radiation technique is possible. The developed pyrometer are capable to detect temperature changes at a span of 0.01 ms.

Item Type: Article
Uncontrolled Keywords: Pyrometer; end milling; infrared radiation; signal processing; cutting temperature, unimas, university, universiti, Borneo, Malaysia, Sarawak, Kuching, Samarahan, ipta, education, research, Universiti Malaysia Sarawak.
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Academic Faculties, Institutes and Centres > Faculty of Engineering
Faculties, Institutes, Centres > Faculty of Engineering
Depositing User: Gani
Date Deposited: 13 May 2019 04:47
Last Modified: 29 Mar 2023 03:41
URI: http://ir.unimas.my/id/eprint/24803

Actions (For repository members only: login required)

View Item View Item