Christopher, Jantai Boniface (2016) A Study on Radian Time Series (RTS) Based Method for Calculating Cooling Load in Equatorial Climates. Masters thesis, UNIMAS.
PDF (Please get the password by email to repository@unimas.my, or call ext: 3914/ 3942/ 3933)
Christopher Jantai Boniface ft.pdf Restricted to Registered users only Download (5MB) |
Abstract
Human being appreciate the relief from discomfort afforded by a modern air conditioning system. In the present day, many houses, offices and commercial buildings or facilities would not be comfortable to stay in without control of the indoor air environment. Air conditioning refers to the control of air temperature, moisture content, cleanliness, air quality and air circulation as required by an occupant, a process or a product in the space. The study was divided into three major parts which consists of cooling load calculation method, Indoor Air Quality (IAQ) and flow simulation. The first part involved the comparison of various methods of cooling load calculation for equatorial climates (hot and humid), cooling load calculation suitable for peak load calculation and cooling load energy analysis, implication of under size air conditioning system and cooling load per square meter for specific building (Building functionality).The results on the first part of the study shows that for building with high ceiling and high volume of occupants, it is recommended that the peak cooling loads per square meter shall be between 0.121kW/m2 and 0.159kW/m2.As for offices, it is recommended that the peak cooling load for high efficient buildings are from 0.058kW/m2 to 0.106kW/m2. The second part of the research is on Indoor Air Quality (IAQ) sampling which was conducted during UNIMAS Convocation in year 2012. The sampling of IAQ was successfully completed with collaborations Department of Occupational Safety and Health (DOSH) Ministry Of Human Resources, Malaysia.
Item Type: | Thesis (Masters) |
---|---|
Additional Information: | Thesis (MSc.) -- Universiti Malaysia Sarawak, 2016. |
Uncontrolled Keywords: | Air conditioning, Air conditioning, Climatic factors, unimas, university, universiti, Borneo, Malaysia, Sarawak, Kuching, Samarahan, ipta, education, Postgraduate, research, Universiti Malaysia Sarawak. |
Subjects: | T Technology > T Technology (General) T Technology > TJ Mechanical engineering and machinery |
Divisions: | Academic Faculties, Institutes and Centres > Faculty of Engineering Faculties, Institutes, Centres > Faculty of Engineering |
Depositing User: | Gani |
Date Deposited: | 30 Jul 2018 07:36 |
Last Modified: | 26 Apr 2023 08:37 |
URI: | http://ir.unimas.my/id/eprint/20997 |
Actions (For repository members only: login required)
View Item |