Wee, Boon Siong and Ho, Manh Dung and Ab. Khalik, Wood and Nazaratul Ashifa, Abdullah Salim and Md. Suhaimi, Elias (2006) Testing the applicability of the k(o)-NAA method at the MINT's TRIGA MARK II reactor. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 564 (2). pp. 716-720. ISSN 0168-9002

[img]
Preview
PDF
Testing the applicability of the k(o)-NAA method at the MINT's TRIGA MARK II reactor (abstract).pdf

Download (71kB) | Preview
Official URL: https://scholar.google.com.my/citations?view_op=vi...

Abstract

The Analytical Chemistry Laboratory at MINT is using the NAA technique since 1980s and is the only laboratory in Malaysia equipped with a research reactor, namely the TRIGA MARK II. Throughout the years the development of NAA technique has been very encouraging and was made applicable to a wide range of samples. At present, the k0 method has become the preferred standardization method of NAA (k0-NAA) due to its multi-elemental analysis capability without using standards. Additionally, the k0 method describes NAA in physically and mathematically understandable definitions and is very suitable for computer evaluation. Eventually, the k0-NAA method has been adopted by MINT in 2003, in collaboration with the Nuclear Research Institute (NRI), Vietnam. The reactor neutron parameters (a and f) for the pneumatic transfer system and for the rotary rack at various locations, as well as the detector efficiencies were determined. After calibration of the reactor and the detectors, the implemented k0 method was validated by analyzing some certified reference materials (including IAEA Soil 7, NIST 1633a, NIST 1632c, NIST 1646a and IAEA 140/TM). The analysis results of the CRMs showed an average u score well below the threshold value of 2 with a precision of better than 710% for most of the elemental concentrations obtained, validating herewith the introduction of the k0-NAA method at the MINT.

Item Type: Article
Uncontrolled Keywords: Neutron activation analysis; k0 standardization method; Reactor neutron spectrum; g-ray spectrometer; Certified reference materials, research, Universiti Malaysia Sarawak, unimas, university, universiti, Borneo, Malaysia, Sarawak, Kuching, Samarahan, ipta, education
Subjects: Q Science > QD Chemistry
Divisions: Academic Faculties, Institutes and Centres > Faculty of Resource Science and Technology
Faculties, Institutes, Centres > Faculty of Resource Science and Technology
Depositing User: Karen Kornalius
Date Deposited: 19 Jan 2016 07:45
Last Modified: 19 Jan 2016 07:45
URI: http://ir.unimas.my/id/eprint/10271

Actions (For repository members only: login required)

View Item View Item