Jamil, Matarul and Mohammad, Abdul Manan and Noor Azland, Jainudin and Amir, Nazaruddin and Abang, Fhaeizdhyall (2020) The Perceptions among the Construction Industry on the Induced Chloride Corrosion for Reinforced Concrete Structure in Sarawak. Journal of Advanced Researchin Social and Behavioural Sciences, 21 (1). pp. 11-18. ISSN 2462-1951

[img] PDF
The Perceptions among the Construction Industry on the Induced Chloride Corrosion for Reinforced Concrete Structure in Sarawak_pdf.pdf

Download (896kB)
Official URL: http://www.akademiabaru.com/submit/index.php/arsbs...

Abstract

Corrosion is the main issue affecting the reinforced concrete structures, especially those built near the river and sea water. The structures constructed could be exposed to the possibility of corrosion and chemical reaction that would reduce the durability and strength of the structures. The main objective of the study is to identify the perceptions and opinions among players of the construction industry such as local authorities, developers, consultants, contractors and other agencies, in relation to the induced chloride corrosion for reinforced concrete structures in Sarawak. The finding shows that 74% of respondents are aware of the effect of the corrosion on the reinforced concrete structures, and only 6.8% of them are not aware of it. The most common grades of concrete delivered by the ready-mixed concrete suppliers are 25 MPa to 50 MPa with a 5 MPa interval. Meanwhile, the respondents agreed that the minimum grade of concrete to combat chloride is 30 MPa, with the highest percentage of about 27.6%. The highest factor that contributes to the corrosion of the reinforced concrete structures is sea water, about 84.8%; this is compared with 6.1% due to carbonation process from fresh water and 9.1% due to chemical attacks. The recommended concrete covers are as follows:50 mm, about 45.2% (highest); this is followed by 75 mm, 25 mm and 100 m with percentages of 20.5%, 17.8% and 2.7% respectively. Approximately 27.4% of the respondents declared that 5 km is the maximum distance within which the structures exposed to chloride attacks would require treatment; this is followed by 2 km, 15 km, 20 km, 30 km and 25 km with percentages of 17.8%, 13.7%, 9.6%, 8.2% and 4.1% respectively. To prevent the occurrence of corrosion and reduced quality of the structures, an overwhelming 94.5% of the respondents agreed that a guideline on the chloride resistance of reinforced concrete structures needs to be produced and implemented in Sarawak.

Item Type: Article
Uncontrolled Keywords: Reinforced concrete structure; corrosion; chloride, unimas, university, universiti, Borneo, Malaysia, Sarawak, Kuching, Samarahan, ipta, education, research, Universiti Malaysia Sarawak
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
T Technology > TH Building construction
Divisions: Academic Faculties, Institutes and Centres > Faculty of Engineering
Faculties, Institutes, Centres > Faculty of Engineering
Depositing User: Tuah
Date Deposited: 10 Nov 2020 08:09
Last Modified: 29 Mar 2023 03:09
URI: http://ir.unimas.my/id/eprint/32691

Actions (For repository members only: login required)

View Item View Item